Contact
Worker packs shuttle boxes

Storage lift systems and paternoster racks

Fire protection ensures availability in vertical storage lift systems and paternoster racks

In addition to compact storage systems, closed storage systems such as vertical storage lift systems or carousel racks (paternoster) optimally meet today's requirements of automated small parts logistics, but place special demands on fire protection.

Even small fires can cause immense damage: from the interruption of logistical processes to the destruction of goods, values and even fixed assets. For managers who operate a storage lift system it is vital to their logistics processes, a fire-related incident would have an immediate negative impact on the company's operability. At WAGNER, we offer you the perfect answer with our comprehensive fire protection solutions for these storage systems. 

RISK ANALYSIS

The main fire risks at a glance

The compact design, often accompanied by dense storage of high concentrations of valuable goods, makes targeted fire extinguishing difficult. Furthermore, the large number of electrical components poses an additional fire risk due to the high degree of automation. In addition, the material of the small load carriers (polyethylene/polypropylene), the packaging (cardboard/plastic) and the stored goods themselves (flammable/self-igniting) pose further risks.

Storage lift system from Kardex loaded with goods on shelves

PROTECTION GOALS

Fire protection requirements

What are your protection goals?

  • Ensuring operational readiness in terms of delivery capability and availability of goods
  • Protection of goods from damage caused by fire, extinguishing agents or smoke contamination
  • Protection of fixed assets
  • Protection against consequential damage and damage to image
  • Personal and environmental protection

BETTER SOLUTIONS IN FIRE PROTECTION

Effective protection against fire-related damage and business interruptions

The particularly compact storage and high material density place special demands on fire protection. We at WAGNER­ have therefore developed a holistic solution for automated, closed storage lift systems and paternoster racks. Thanks to highly sensitive early fire detection in combination with residue-free extinguishing, we ensure the maintenance of logistics processes and the ability to deliver for their customers worldwide.

Our highly sensitive TITANUS®­ aspirating smoke detectors detect the finest smoke particles at the earliest possible stage by constantly taking air samples in the protected area, thus enabling countermeasures to be initiated in good time in the event of an alarm. Our system for early fire detection is 2000 times more sensitive than conventional point-type detectors and thus detects a fire much earlier and with maximum immunity to false alarms.

The FirExting® N2 diffuser gas extinguishing system with the patented N2 diffuser nozzle enables uniform flooding with optimum distribution of the extinguishing gas N2 in the storage system in the event of a fire. This ensures that the extinguishing gas is distributed evenly over the entire height of a storage system up to 30 meters high. 

To compensate for design-related leaks in the storage system and to ensure reliable fire protection beyond the extinguishing hold times required by VdS, for example, further flooding is initiated shortly after the initial flooding. These extinguishing hold floodings serve to maintain the effective extinguishing gas concentration in the storage system at the best possible level. To this end, additional extinguishing agent containers are triggered at intervals. 

The gentle introduction of the extinguishing gas with very low dynamics also prevents turbulence from damaging or even displacing the stored goods. 

The fire is thus extinguished effectively and, above all, without leaving any residue. Damage to infrastructure and stored goods caused by water-based extinguishing agents—water, spray mist, foam—as well as powder or aerosols is avoided. 

And all this without losing any storage space in the storage system. 

IN PRACTICE

Holistic fire protection in a storage lift system

3D view of the WAGNER systems in a storage lift system

BENEFITS

Our solution ensures operational readiness and availability

An icon with a shopping trolley with a heart on it

Goods and values

Reliable protection of your goods and values from damage caused by fire using non-residual extinguishing agents.

An icon of a power button

Operational readiness

Protection of your supply chain by ensuring uninterrupted ability to deliver.

An icon of a loudspeaker

Reputation

Prevention of fire-related consequential damage and damage to image.

Stacked squares

Modular

Thanks to their modularity, our fire protection systems can be adapted at any time and "grow" with the storage system.

A tree leaf icon

Sustainability

By using the inert gas nitrogen, our system is environmentally friendly, residue-free and non-destructive.

Dirk Band: Director Sales Division

Our innovative technology protects your goods and values

We will be happy to advise you individually.

Dirk Band

Director Sales Division

+49.511.97383-0